Suburban sf 42 furnace troubleshooting. Why repair … Suburban Furnace SF-42--Does not stay on.
Suburban sf 42 furnace troubleshooting But they do have a dealer/service center locator web page that should help you find a dealer, etc. I'm stumped. Discover key features of this efficient heating solution for RVs and mobile homes, learn how to maintain optimal performance, and ensure your furnace runs smoothly all My Suburban sf-42 furnace recently started operating intermittently by running as advertised and strong and turning off when the cabin temp was I've learned a lot by doing the trouble shooting and repairs myself. That would This Suburban RV furnace troubleshooting guide will show you what to do in the event that your furnace is malfunctioning. Suburban Furnace Motor (SF-42/SF-42F) 233103MC. Junior Member . Learn maintenance strategies, key inspection steps, and when to call a professional for optimal furnace performance. Trouble Shooting Flow Chart (Furnaces Equipped with Tim E Delay Relay) 27. When I turn on the furnace I hear a click in the furnace when the furnace is turned on. My research shows it might be a faulty sail switch. $74. If that checks out good then you can begin testing. Toggle navigation. Fear not! This troubleshooting guide is here to help you diagnose and resolve common RV furnace issues, keeping you snug and SUBURBAN SFV-20Q furnace pdf manual download. Suburban's SF-Q Series furnaces provide maximum heating performance in a ducted unit, with capacities from 20,000 to 40,000 BTU/h. 47. In order for the furnace to operate in conformity with generally accepted safety regulations, the installation instructions must be followed. Suburban Furnace Bottom Duct Kit (520576) SF-20/25/30/35Q/FQ. 24,217 Satisfied Customers. com Google Click Here to Login: Files: Vendors Registry. 08. The first (Kit #1) has the old style burner access gasket which makes kit #1 applicable to the SF-42F between serial numbers 934701426 and 094101431, the second (Kit #2) has the new style burner access gasket which is applicable to the SF-42F above serial Resetting the Furnaces in Suburban RV. Solution 01: Check for Gas Supply and Tanks. It would then cycle through the 3-4 attempts to ignite, light, Suburban SF42 Furnace. Learn step-by-step solutions, maintenance advice, and when to call in a pro. His Playlist of furnace repair videos may also be helpful. How do you reset the Suburban RV furnace? It is necessary to turn off the propane gas supply from the furnace and close the propane valve. Furnaces. Furnace must be turned on Troubleshooting your Suburban SF-30F gas furnace doesn’t have to be daunting. If you are getting cold air even during the lockdown mode, then this part is the culprit. We have a furnace troubleshooting procedure in our forum Library (button in the menu above). Attached Files. The way I was able to trouble shoot it was to remove the furnace to alongside the camper on a table and rehook the gas line up using a extension hose. Backdrop of the Nehalem River. Suburban SF-42 ; Suburban SF-25FQ Page 7 FurnaCE rEMOVal SF-20/25/30/35/42, SF-20Q/25Q/30Q/35Q/42Q, SFV-20/25/30/35/42, SH-35/42 and SHD-2542 1. View online or download Suburban SF-42FQ RV Furnace Installation Instructions Manual SF-42 2609A S6U01-1720 SF-42F 2610A S6U01-1721 SF-42FQ 2610A S6U01-1721 SF-42Q 2609A S6U01-1720 Suburban Furnace Core replacements give an alternative to pulling and replacing old and worn parts, one at a time. 95 Winnebago Adventurer 34 on Chevy P32 chassis with 7. Furnace shuts off after 30 seconds. A couple friend of ours Suburban SH-42 Furnace Tune-Up Kit Pdf User Manuals. So, do not worry; it is effortless to locate it. Although we have made advancements in every field, it is impossible to keep machines running all the time. Hello "Removing a newer vertically mounted Suburban furnace is a pain. Suburban SF 42 control board. Owner at Randalls Mobile Rv repair. See posts with no answers. time for fan. Jan 2, 2022 #1 Isaac-1 Well-known member. 1996 vintage. Suburban Furnace Time Delay Relay Board Kit (521314) SF-T Series. I figured it had something to do with the charge level of my batteries but then couldn't get it to ignite on shore power. In order for the furnace to operate in conformity with generally Suburban Sf-30FQ furnace, about 6 years old. Anyone have a suggestion on how to diagnose this problem? Thank you. Anyone have advice on a fix Journey with Confidence RV GPS App RV Trip Sf-30 and sf-42 are similar. Here's the manual. Home; Shop . ) Suburban Furnace Troubleshooting Help Needed. Joined Suburban RV FURNACES SERVICE MANUAL. 3 Caution Notes Read all instructions before using the Suburban Gas Furnace. A few seconds later another click. This happened 3 times, then would turn off. Backfire continue intermittently as long as the furnace continues to run. I installed a thermostat with the same P/N the manufacturer installed, P/N 9430A338. In order for Model No. Trouble is a constant flame on/flame off situation. Turn on Thermostat 2. Suburban SF-42 Furnace doesn't work on Batteries: briankstan: RV Systems & Appliances: 9: 10-20-2014 11:00 AM: Good Suburban furnace service. Airxcel Suburban SF-42Q Installation Instructions Manual (24 pages) Brand: Airxcel Struggling with your Suburban SF 25 furnace? Our comprehensive guide offers practical troubleshooting tips for common winter issues, from strange noises to no heat output. More similar videos here: Suburban SF-42F Pdf User Manuals. The furnace will run for about 5 min then shut off. of your Furnace 4. which might interfere with the installation. BLACK FRIDAY SALE! Get 20% off TODAY only! Visit https://myrvworksstore. Locate the furnace near lengthwise center of the coach. Dinosaur The furnace is a Suburban Model # SF-30 2321J Serial # 054908950 and was working fine up until can I get access to the furnace to start trouble shooting from in the cabin area OR is access only from the outside where the intake/exhaust ports Furnace gremlins? Suburban SF-42: Bob&Pat: General Maintenance and Repair: 8: 04-07 Suburban SF-20 Furnace Replacement Core Pdf User Manuals. pdf . Skip to content. Suburban Furnace 2592A 42,000BTU (SF-42VHQ) Vertical/Horizontal Mount. Join Date: Jan 2019. I'm battling a strange issue with a Suburban SF-42Q furnace, I've had 2 different techs come out throw parts at it, deep clean it and the issue still remains. Suburban SF-42 ; Suburban SF-42Q 95 Winnebago Adventurer 34 with Suburban SF-42 furnace. txt) or read online for free. If your furnace is not producing any heat, the first thing to check is the thermostat. pdf), Text File (. My furnace quit on the last trip. Suburban 232806 Furnace Ignition This guide is on Troubleshooting a Suburban RV Furnace. Is there a test to confirm this? Can the sail switch be replaced without removing the furnace. RV Tech. One of the area’s biggest employers, the corporation today runs a 300,000 square foot manufacturing complex. I cannot hear the gas valve opening or the ignitor “clicking”. after 22yrs. 3. Suburban Furnace Core 2608A (SF-25FQ I just replaced my SF42 furnace in my 2000 Journey 34D. Suburban is not liable for damage resulting from failing to follow instructions contained in this, and any other Suburban documentation relevant to this appliance. View All; Awnings. Menu 42% of RVers had heating issues. Choose a location for installat~on out of the way of wires, pipes, etc. Thread starter thewhitt; Start date Nov 4, 2007; The friendliest place on the web for anyone with an RV or an interest in RVing! One time the furnace failed while I was boondocking, so I removed the sofa to gain access to it for troubleshooting. Customer: I have an rv furnace - suburban sf-42 and if i cover the air intake port on the outside of the motor home the furnace will ignite. square. . Keep your home warm and cozy this winter by mastering your furnace’s care with our expert insights. Suburban SF-35FQ won't light. Menu. Browse through our online database of information and resources listed below or contact the Suburban Customer Service Team at (423) 775-2131 for help with your Suburban climate control appliance (furnace or wall heater units), water heater, cooktop, range, griddle, slide-out kitchen, or microwave oven. Suburban SF-35F ; Suburban SF-30Q suburban SF 42 problem suburban SF 42 problem. Turn on - fan comes on normally. Furnace Specifications (SF, SFV, SH, and SHD-2542 Model Furnaces) 28. , near you. according to the sequence of operation the heater looks for the switch to be open before powering the Suburban SF-42 furnace won't come on: SubVetRet: RV Systems & Appliances: 3: 09-27-2015 07:17 PM: Zero response from furnace after several power outages The SF-42 can be removed from the outside ; provided the coach builder installed it with the 8"x16" access panel . SF-Q Series Furnace; SF-FQ Series Furnaces. This article explores common issues like ignition failures, heating inconsistencies, and unusual noises. Thread starter FDeanGr; Start date Oct 10, Please read my article on Furnace Troubleshooting to understand how it works and what each component does. Posts: 5 Suburban SF-35 Propane Furnace won't ignite. Thread starter arhayes; Start date Jan 23, 2017; Tags mygrandrv Jan 23, 2017 #1 arhayes Senior Member. TXiceman: RV Systems & Appliances: 8: 05-26-2014 09:02 PM: Help required - starting Suburban SF-30F furnace: jacksonmacd: RV Systems & Appliances: 1: 04-21-2014 07:47 AM: Suburban NT 30 S SUBURBAN MANUFACTURING COMPANY 676 Broadway Street Dayton, Tennessee 37321 423-775-2131 www. Furnace comes on runs for awhile and shuts off before reaching thermostat temp. SF, SH and SHD-2542 The Suburban RV furnace’s reset button is either red or yellow. 2 TABLE OF CONTENTS Page Trouble Shooting Flow Chart (Furnaces Equipped with Time Delay Relay) SF-42, (F) 520864 Bottom Duct Kit W/Gasket SH-42 (F) SHD-2542 Wall Thermostats INSTALLING THE FURNACE SF-42F NOTE: Before installing the furnace "X dimension as illustrated in Figure 2 must be determined. 0 Members and 2 Guests are viewing this topic. The first thing I checked was the thermostat to make A multi-meter is definitely helpful in troubleshooting. Rv suburban appliance furnace sf used appliancesSf furnace suburban Suburban furnace sf rv navigation postRv appliances used rv suburban sf-42 furnace motorhome parts for sale. , RV Technician, Darren Koepp, has an intermittently working Suburban RV Furnace unit. I have a SF-42 RV gas furnace that is not working. _____ 99DSDP 3884 Help required - starting Suburban SF-30F furnace: jacksonmacd: RV Systems & Appliances: 1: 04-21-2014 07:47 AM: Suburban RV Furnace Parts and Products for sale! Powerful heating performance for your RV. What did not surprise me is the #1 problem is voltage. Suburban SF-35Q Furnace. Furnace does not go into lockout. The blower runs about 10 seconds and then shuts off. Blogs: FAQ: Members List: iRV2 Groups: Calendar: Mark If the furance blower motor doesn’t spin back up after the inside temp goes lower then the thermostat is set at then troubleshooting ANY LP issue would get you nowhere. When tstat request is made furnace cycles on normally. Began taking this furnace apart and found some major issues birds nest built in the burner area, along with other faulty components. Quick view Compare Add to Cart. Also for: Suburban sf-25q, Suburban sf-30q, Suburban sf-35q, Suburban sf-42q, Suburban sf-20fq, Suburban sf-25fq, SH-35 • SH-42 • SH-35F • SH-42F • SHD-2542Q. 95 Winnebago Adventurer 34 with Suburban SF42 furnace. A&E Awning Parts; Carefree Awning Parts; Girard Awning Parts; Lippert Solera Awning Parts; Heating & Cooling. pdf (4. 8 out of 5 stars 56 Suburban SF-42. If any parts are found to be damaged, do not . It is on a 2010 Cardinal Struggling with your Suburban SF-30 furnace? This comprehensive guide tackles common issues like strange noises, inconsistent heating, and shutdowns, especially when you need warmth the most. Yet, at only 7 1/2 I have a Big Horn 5th wheel with a Suburban SF-42 furnace that stopped working this morning. We tackle common issues like ignition problems, thermostat malfunctions, and airflow restrictions that can disrupt heating when you need it most. Furnace restarts when heat is call for. In. Moreover, turn off the furnace from the main circuit breakers of the RVs. Suburban sf-42q furnace. 42. The connector coming from the coach only has 3 wires; 2 yellow wires and one white wire. Furnace Suburban DD-17DSI Service Manual. I have an issue with Suburban sf-42 furnace. 1. Last edited by a It was quite obvious, on seeing this, WHY we have had so much trouble with this furnace since we bought our FR Wildwood from the Suburban Furnace Trouble Shooting. I ran completely out of propane. The first step when troubleshooting your Suburban RV furnace is to check whether there’s an issue with the power supply. When the thermostat calls, Suburban SF 42 Shuts Down after 30 seconds iRV2. - SUBURBAN DIVISION 676 Broadway Street Dayton, Tennessee 37321 423-775-2131 www. Suburban Master Parts List; Suburban Furnace Service and Training Manual SH-42; Suburban Furnace Model SH-42 Tune-Up Kit. Our 05 Wildwood came with an under-the-range mounted Suburban SF-30 propane furnace, which worked fine when we bought our burban/SF-20-25-30-35-42_Furnace_Suburban. Posts: 23 Ok, thanks for that Suburban Rv Furnace Wont Ignite when trying to ignite lets look and see why this furnace is not working and how to troubleshoot it so we can get it repaired Suburban sf-20q furnace installation instructions manual pdf view Suburban furnace sfv-42 Furnace suburban sf 30f propane ignite removing intake. Trouble started when it wouldn’t ignite. com SUBURBAN GAS FURNACES INSTALLATION INSTRUCTIONS FOR MODELS SF-20 • SF-25 • SF-30 • SF-35 • SF-42 The design of the furnace has been listed for installation in recreational vehicles only. Then after Troubleshooting a SF-42 Suburban furnace with ignition problems. Manuals; Troubleshooting Flow Chart (Furnaces Equipped with Fan Control Module Board) 32. 4 liter engine. I THINK I may have a circuit board problem. $178. I do not hear the burner start and the blower does not come on. Previous topic - Next topic. Greg Suburban Furnace SF35 SF42 Questions: CoachStreamr: RV Systems & Appliances: 2: 02-14-2018 08:12 PM: Suburban SF35 not lighting up: Dank1945: RV Systems & Appliances: 1: 01-16-2018 06:26 AM: Suburban Suburban RV FURNACES SERVICE MANUAL. 24,195 Satisfied Customers. Check your circuit breakers and make sure they are in the “on” position, then make sure that all wires connecting to the unit are properly connected. Explore the solutions below to ensure comfort in your trailer during chilly days. TrOublE ShOOTinG GuiDE SUBURBAN RV FURNACES with FAN CONTROL MODULE BOARDS 12 VDC HEATING SECTION Check thermostat wire connections, contact Clean points, However, if the furnace stops working, you will need to check on a few things for effective troubleshooting. What year is the SF-35 , I'll try and find a wiring schematic. Discover effective solutions, from checking drafts to replacing faulty ignitors, and learn essential maintenance tips to enhance efficiency. Suburban SF-30 Furnace Troubleshooting. Cautions & Safety Information. Buy Furnace Motor Replacement for Suburban RV for SF-42/42F 233103: manufacturer contact information, step-by-step troubleshooting guides, and help videos. ST-42 Water Heater; ST-60 Water Heater; Advantage Tankless Water Heater Control; Replacement Door Panel; Vent Cap; Climate Control. That relay supplies 12V DC to the furnace control board to start the blower. SF-20 heating system pdf manual download. site/ and enter code BLACKFRIDAY22 at checkout. Thread starter Stoliguy; Start date Sep 18, 2014; folks usually just replace the board and their problems seem to disappear. 8. The furnace checks out good and will start up and run when I short the 2 blue wires in the furnace together. 5v 1-I disconnected the lead from the furnace going to the furnace breaker and connected a lead from the battery + at Suburban SF-42 furnace still not working! Started by ClydesdaleKevin, December 14, 2019, 04:41 PM. FURNACE REMOVAL SF-20/25/30/35/42, SF-20Q/25Q/30Q/35Q/42Q, SFV-20/25/30/35/42, SH-35/42 and SHD-2542 1. SUBURBAN MANUFACTURING COMPANY 676 Broadway Street Dayton, Tennessee 37321 423-775-2131 www. One thing I found after changing them is a drop of 2 volts from the 12 volt breaker and the voltage going to circuit board which is most likely my When the thermostat calls for heat, it fires a relay located overhead. Troubleshooting Pilot Light Ignition of Suburban RV Furnace. Checked power at furnace (yellow wire) and at sail switch when I manually operate sail switch The furnace works great now and the issue was one of the gas solenoids. Suburban Furnace Model SF-42F Tune-Up Kit comes in two variations. When troubleshooting your Suburban SF 42 furnace, it is important to be aware of common issues that can arise. Are you having trouble with your Suburban RV furnace? If so, it’s important to resolve the issue as quickly as possible. Blower not coming . Also for: Sf-25, Sf-30, Sf-35. Delete from my INC. With practical advice on diagnostics and repairs, Suburban Furnace SF35 SF42 Questions: CoachStreamr: RV Systems & Appliances: 2: 02-14-2018 08:12 PM: Suburban SF42 Furnace & Thermostat Problems: K5EAG: Winnebago Industries Owner's Forum: 1: 03-07-2017 05:04 PM: Suburban SF42 Furnace: geezerb: Class A Motorhome Discussions: 4: 11-25-2013 12:41 PM: suburban sf42 furnace. Struggling with your Suburban SF 42 furnace? This comprehensive article tackles common issues like strange noises, inconsistent heating, and shutdowns, providing essential troubleshooting tips. Join Date: Mar 2012. Diagnosing the cause of a Suburban RV furnace not lighting requires a systematic approach similar to assessing residential space heaters. Why repair Suburban Furnace SF-42--Does not stay on. Quick view Add to Cart. I have an extra sail switch now. How to replace the fan motor in a Suburban SF-42 furnace in a motorhome or travel trailer. Keep ©2025 Suburban, an Airxcel Brand - All Rights Reserved | 676 Broadway Street, Dayton, Tennessee 37321 | Phone: (423) 775-2131 View online or download Suburban SF-30 Service Manual, Installation Instructions Manual, User's Information Manual. 5v 1-I disconnected the lead from the furnace going to the furnace breaker and connected a lead from the battery + at the breaker end. Suburban Furnace SF-42--Does not stay on. Advertisement. Back in ’16 when I bought this RV, the gas floor furnace worked very well in concert with the heat pump. It offers practical steps for diagnosing problems, from checking the thermostat to inspecting the blower motor. Pretty standard Suburban SF-35 propane furnace with (2) 30# propane bottles with auto change over regulator. Expert tips for suburban rv furnace maintenance and repairs. china3: Tiffin Owner's Forum: 2: 09-02-2013 03:58 PM: Snowbirds Come South! 6 Figure 2 SF Figure 2A SH VENTING Venting - By definition of a Direct Vent Sealed Combustion Furnace, it must be vented to the outside atmosphere and also draw combustion air from outdoors. Suburban SF-25F Suburban SF 42 Furnace problem. I am in same boat. SF-20 furnace pdf manual download. I opened up the cover and then took the faceplate off the furnace. SUBURBAN MANUFACTURING COMPANY Post Office Box 399 Dayton, Tennessee 37321 a substdlary 01 AIRXCEL, InC CERTIFIED SUBURBAN GAS FURNACES INSTALLATION INSTRUCTIONS FOR MODEL SF-42 The design of the furnace has been listed for installation in recreational vehicles only. Suburban SF-20FQ ; Suburban SF-42FQ Troubleshooting Your Suburban RV Furnace Check the Power. There's a troubleshooting guide on page 27. If I turn off and back on, will run again it heats but will then do the same thing. My Suburban SF-42Q will not start. Suburban, an Airxcel Brand Suburban Gas Furnace Operation Guide REV 2246 p. The digital thermostat would click when turned on and I could hear a click at the furnace. View online or download Suburban SFV-42 Service Manual, Service Training Manual, User's Information Manual. Start with the leads from the control in the A/C to the I've read Gary's excellent troubleshooting guide and from what I can see, the furnace may be overheating and the High Limit Cut-off is shutting off the burner. Every suburban furnace system in RV is equipped with a propane tank. Struggling with your Suburban SF 20 furnace this winter? Discover effective troubleshooting tips for common issues such as failure to start, insufficient heat, and strange noises. Every Suburban RV furnace has two blower motors under the hood and one combustion camper. Hello, Need some help with my SF-20 unit. Start new topic; Recommended Posts. What Country Produces Suburban Furnaces? Amazingly, Suburban still manufactures furnaces in Dayton, Tennessee, where it was founded. That's the click. Once outside temp increase, it will cycle as it should from the thermostat. 45. Turn on furnace with the switch on the outside. Trouble Shooting Flow Chart (Furnaces Equipped with Fan Control Module Board) 28. The burner will light for a second or two and then go out. 0 out of 5 stars Works for pre-2001 Suburban SF-42 Furnace Heaters. Also for: Suburban sf-20q, Suburban sf-25q, Suburban sf-30q, Suburban sf-35q, Suburban sf-42q, Suburban sf-20fq, Suburban sf-25fq, Suburban sf-30fq, Sign In Upload. Furnace Suburban SH-42 User's Information Manual (3 pages) Furnace Suburban SH-35F Installation Instructions Manual (8 pages) Page 1 676 Broadway Street Dayton, Tennessee 37321 423-775-2131 www. Very easy install. SF-35VHQ. There has been a bug screen on the furnace for 7 yrs and never had this problem before this season. Swiftly addressing furnace issues is crucial for a pleasant RV journey. After about 15 seconds I hear the same click but nothing has happened. Today's question comes from Bar here is my troubleshooting steps today, battery voltage 13. 2021 Winnebago 36Z, Suburban SF-42Q furnace. I Suburban Furnace Sail Switch 232261. A faulty gas valve is the usual culprit, but you could be looking at firty vents or electrical failures here is my troubleshooting steps today, battery voltage 13. 60. Upgrade your RV heating with the versatile Suburban Furnace SF-35VHQ (2588A) that provides powerful, quiet heating in a compact design. We have seen such a issue with our suburban furnace last year. In order for We have 3 Airxcel Suburban SF-42Q RV Furnace manuals available for free PDF download: Installation Instructions Manual, User's Information Manual . 45. The Suburban RV furnace resets button is in the blower compartment. 4v input to the circuit board. Number of Parts Required AIRXCEL, INC. Rv furnaces (48 pages) Furnace Suburban DD-17DSI Service Manual. It was obvious the ignitor was not sparking, so I closed the gap and it has worked going on 2 years now. Igniter would start again, flame would start, then go out. The manual instructs technicians on properly installing, maintaining, and repairing the furnaces. $23. Yet, at only 7-1/2 Inches high, they can be easily installed in My furnace has worked great until late last night. Proper maintenance and occasional resetting of the furnaces in your Suburban RV are essential for optimal performance and comfort during your travels. I need to replace the brake master cylinder and. Suburban Furnace Service and Training Manual SF-42Q; Suburban Furnace Model SF-42Q Tune-Up Kit. and Serial No. Search. Discover effective troubleshooting techniques, maintenance tips, and vital information on this popular propane furnace, designed for small spaces like RVs. This guide and experimentation fixed 78% of the issues! (Same source; see, we do our research. Sequence of Operation (Time Delay Relay Equipped Furnaces) 30. Upload. SF-Q Series Furnaces. The furnace blower does not turn on. Ideal for vertical or horizontal mounting. Suburban replacement core for furnace series #s SF-35, SF-35Q, SF-42, SF-42Q, and SF-Q (2564A) Search; RV Owners; Dealer/Service; OEM; Products; Support; cost-effective and time-saving alternative to replacing your entire furnace with the Suburban furnace Core Replacement Module Furnace Core Module slides into the existing cabinet saving Suburban RV furnace troubleshooting guide to keep your furnace running smoothly all winter. 01-12-2019, 09:42 PM wellsit. Add to my manuals. I found the video below very informative. Equip yourself with practical solutions to keep your home Here's a link to a You Tube Video on troubleshooting a Suburban RV furnace with the exact same problem you have. View and Download Suburban SF-42F installation instructions manual online. 43. It will run (fan) for 30 seconds then shut down. - SUBURBAN DIVISION. Discover essential maintenance tips and a step-by-step approach to ensure your furnace runs smoothly. No Heat. SF-42 Above S/N 924201894 6 Figure 2 SF Figure 2A SH VENTING Venting- By definition of a Direct Vent Sealed Combustion Furnace, it must be vented to the outside atmosphere and also draw combustion air fro m outd oors. Remove the vent cap assembly from the outside access door by removing applicable screws, also the four (4) screws retaining the door to the frame. Suburban (2399A SF-42Q Ducted Furnace; Suburban New SF-30FQ 2391A DUCTED Furnace for RV Camper Motorhome Trailer; Suburban Furnace - Thermostat Wiring Question 12-15-2020, 02:37 PM Yesterday, while rerouting and untangling wires to make space for my solar/lithium conversion, I disconnected a green/black wire from the blue wire going into the furnace and untangled it from a mess of other wires. My SF-42 doesn't have a yellow wire . Suburban, an Airxcel Brand Suburban Gas Furnace Operation Guide 2292 p. The issue is it is that as it fails to light say 60-70% of the time today but then next week it runs fine. Suburban SF-35 Furnace Troubleshooting Guide. 2 TABLE OF CONTENTS Page Trouble Shooting Flow Chart (Furnaces Equipped with Time Delay Relay) SF-42, (F) 520864 Bottom Duct Kit W/Gasket SH-42 (F) SHD-2542 Wall Thermostats Troubleshooting Flow Chart (Furnaces Equipped with Fan Control Module Board) 31. Suburban Furnace Gas Valve Solenoid Kit for SF and SFQ • 521074 Suburban Furnace Gas Valve Solenoid Kit for SF and SFQ • 521074. If your propane tank has gas in it and there are no obstructions, then start checking different parts to see if they are functioning okay. Troubleshooting SF-42Q No Heat, Fan Is Blowing. Suburban SF-42Q furnace will not start up: hforrey: RV Systems & Appliances: 10: 11-20-2016 04:08 PM: Suburban SF-42 furnace won't come on: SubVetRet: RV Systems & Appliances: 3: 09-27-2015 07:17 PM: slide out wont come in leveler wont come up. Suburban Furnace I recently replaced the fan motor and sail switch on an SF42 furnace. My problem is the fan is running but the propane does not ignite. thanks for the replys after some more troubleshooting i traced the problem to the sail switch sticking closed after initial heat cycle. Journey with Confidence RV GPS App RV Trip 01-19-2015, 07:42 PM slyvt. You will see the blower motors aside from the button. Therefore, it is imperative that the vent be unobstructed and there must be a seal between the exhaust and intake (caulking) . The furnace was inspected before it left the factory. Checked power at furnace (yellow wire) SF-Q Series Furnaces Maximum heating performance in a low-profile design. The fan would turn on, I heard the igniter clicking and no flame. Burner Ignites, burns 6 - 7 seconds, goes out (Warm exhaust present) 4. This again is seen by many new RV furnace buyers. Suburban Furnace SF-Series And SH-Series Blower Housing/ Burner Assembly/ Combustion Chamber Screw 121857. yes. Tune-Up Kit Contents: Item# 22 Electrode With Lead 232286; Item# 23 Burner Assembly 010799; Item# 59 Limit Switch 232505; Item# 45 Sail Switch 232261; Item# 12 Burner Access Door Gasket 071263 _____ SUBURBAN FURNACE SF-42Q EXPLODED PARTS SUBURBAN GAS FURNACES USER’S INFORMATION MANUAL For Models SH-35 • SH-42 • SH-35F • SH-42F SF-20VHQ • SF-20VHFQ • SF-25VHQ • SF-25VHFQ SF-30VHQ • SF-30VHFQ • SF-35VHQ • SF-35VHFQ This book contains instructions covering the operation and maintenance of your furnace. 2. Remove the door to gain access to the furnace. ' 2. Luckily, there are things you can do right now to get your furnace up and running without having to wait for a technician to 6 Figure 2 SF Figure 2A SH VENTING Venting - By definition of a Direct Vent Sealed Combustion Furnace, it must be vented to the outside atmosphere and also draw combustion air from outdoors. 4. Stay warm this winter with essential maintenance tips to keep 2021 367BHS Suburban Model SFV-35Q Troubleshooting Help 11-16-2022, 05:38 PM. 2551A : Suburban SF-20FQ Series Furnace: Features. _____ SubVetRet 2014 Bighorn, 2012 F350 Super Suburban SF-42 Furnace Intermittent iRV2. You seem to have covered the bases, but maybe a glance through the procedure will help. 142 Sq. One must start with the most likely reason before considering rare causes. Page 1 INSTALLATION INSTRUCTIONS FOR MODELS SF-20 • SF-25 • SF-30 • SF-35 • SF-42 The design of the furnace has been listed for installation in recreational vehicles only. No, I haven't recently had About Press Copyright Contact us Creators Advertise Developers Terms Privacy Policy & Safety How YouTube works Test new features NFL Sunday Ticket Press Copyright 95 Winnebago Adventurer 34 with Suburban SF-42 furnace. Having never delved into the deep-dark secrets contained within the shiny metal case of the device called "The Heater", recent threads here on the forum have led me to learning more about this mysterious appliance. Turn on thermostat, set temp higher than room temp, fan starts and runs for a minute then shuts off. In order for Winter is here and the furnace went out in my trailer! Watch as I walk you through the diagnosis and troubleshooting, and replace the gas valve, igniter, sai Trouble Shooting Flow Chart (Furnaces Equipped with Tim E Delay Relay) 27. It would surprise me sometimes in the cold of the high desert in the early Suburban SF-42FQ RV Furnace Pdf User Manuals. Ive also spent about an hour on "YOU TUBE" under RV Furnace troubleshooting. By GlennWest October 26, 2018 in Technical Tips and Tricks. Sign In Upload. Fit For Suburban RV Furnace Parts 232286,Single Probe Gas Furnace Igniters Electrode with Wire Assembly, Camper Furnace For Suburban 232286 Above 934701426 SF-20, SF-25, SF-30, SF-35 (SF Series) 4. It provides specifications, installation instructions, troubleshooting guides, and maintenance information for various furnace models including DD, NT, P, SF, SH, and SHD. My procedure: 1. Sign In. Had someone outside by furnace exhaust, can't hear any clicking so SF-20-25-30-35-42_Furnace_Suburban - Free download as PDF File (. Furnace was working fine until this trip. WStue: RV Systems & Appliances: 6: Your RV furnace is a vital component, especially during chilly nights or winter travels, ensuring warmth and comfort inside your mobile haven. Here’s how to troubleshoot an RV furnace that won’t turn on or stay Suburban Furnace Motor (SF-42/SF-42F) 233103MC. how to diagnose a furnace that runs for 30 seconds and shuts off. Motor wires are red power and black ground . Home / Camper Rules. Delete from my manuals. View Cart (0) PDX RV LLC. pdf Author: Mark Created Date: 8/21/2016 11:18:49 AM If you are in warranty then the company would replace it. How to Solve Suburban RV Furnaces Not Igniting. Discover effective troubleshooting tips for your Suburban SF 30 furnace in our comprehensive guide. The document is a service manual for Suburban RV furnaces. SF-42F furnace pdf manual download. The flame would start, I would feel heat in the exhaust, then the flame would go out. Turn up thermostat and furnace restarts. These 2 blue wires are part of the 4 wire connector which comes from the furnace. Anyone having questions in regards to my problem please feel free to ask. A malfunctioning furnace can result in major problems such as frozen pipes – especially if you’re camping in a cold climate. Reviewed in the United States on April 17, 2024. rvcomfort. One part to check is the flame sensor. It will stay lit and produce good heat until the rv reaches thermostat temp. Fan goes on, runs approximately 1 minute before step 3. com Google Click Here to Login I'm doing this from memory, so this may not be exact, but I believe it is very close. The refor e, it i s imper ativ e tha t th e vent be unobstr ucted and there must b e a seal betw een the exhaust and inta ke ( caul king ) . Fan stays on, burner reignites in about 30 seconds, burns 6 - 7 seconds, goes out (Again Warm exhaust) 5. Suburban replacement core for furnace series #s F-42F, SF-35F, SF-35FQ, SF-42FQ, SF-FQ (2563A) Search; RV ST-42 Water Heater; ST-60 Water Heater; cost-effective and time-saving alternative to replacing your entire furnace with the Suburban furnace Core Replacement Module Furnace Core Module slides into the existing cabinet View and Download Suburban SF-20 user's information manual online. This book contains instructions covering the operation and maintenance of your furnace. Maintenance. Been having inconsistent burner shutoffThe thermostat will. RV Thermostats. Key steps outlined include selecting an Title: SUBURBAN FURNACE SERVICE MANUAL. 36. _____ Rob Hentges 31ft Dutchmen Royal Classic Tags: ace, furnace: You Suburban SF-42 Furnace doesn't work on Batteries: briankstan: RV Systems & Appliances: 9: Have a Suburban SF-35 furnace issue in our 2018 Solitude 384GK. These are red or yellow, depending on the model of the furnaces. $89. The guts of the furnace can be slid out through the opening , after disconnecting the propane and wiring , 2018 374th Solitude Suburban SF 35q furnace won’t cycle in colder temps (below 45). SF, SH and SHD-2542 Electrode Gap Specifications & Positioning. Thread starter divinIN; Start date Dec 14, 2023; D. I hear a click sound, nothing happens. Struggling with your Suburban SF-35 furnace? Our comprehensive troubleshooting guide tackles common issues like flickering pilot lights and strange noises. URL of this page: HTML Link: Related Manuals for Suburban SF-42. Suburban's SFQ Series furnaces provide maximum heating performance in a ducted unit. Here are some common problems and their potential solutions: 1. SF-42 furnace pdf manual download. So after all my hours of troubleshooting it turned out to be a bad board. RemyJL When you reinstall the unit, leave all the duct work off and run it. 42 AM. Download. Suburban furnace sf-42. The furnace's flame stays lit for a little while and Suburban Furnace Control Board (NT-12-S/ SF-42/ NT-25-K/DD-17DSI) 520820MC. and maintenance. $119. Suburban Furnace Service Manual. Check the specifics for your furnace, but here is essentially what you are looking for, a gas valve Check first to be sure that it isn't the fuse in your main power center for the furnace. Will do assembly video a Suburban SF 30 Furnace Troubleshooting and Repair. Darren from My RV Works just posted a very thorough furnace troubleshooting video. View online or download Suburban SF-35 RV Furnace Service Manual, Installation Instructions Manual, User's Information Manual. Joined May 28, 2014 I got Furnace runs for about 15 minutes then shuts down. It is not uncommon for a machine to stop working randomly. I am replacing the control board the electrode flame sensor. It's in the RVforum Suburban Model SF-42 Gas Furnace 40,000 BTU . I have a Suburban SF25 furnace in my 2004 Springdale Trailer. Tune-Up Kit Contents: (To order just an individual part, click onto the item# / description below) Item# 22 Electrode With Lead 232286; Item# 23 Burner Assembly 010799; Item# 62 Limit Switch 232735; Item# 44 Sail Switch I have a Suburban NT30 in my 5th wheel. Also for: Sf-25, Sf-30, Sf-35, Sf-42, Sf-20f, Sf-25f, Sf-30f, Furnace Suburban SF-42 Installation Instructions Manual (10 pages) Furnace Suburban SF-42F Installation Instructions Manual (8 pages) Remember: Before troubleshooting your furnace, ask yourself these questions to make the process easier. com SUBURBAN GAS FURNACES USER’S INFORMATION MANUAL For Models SF-20Q • SF-25Q • SF-30Q • SF-35Q • SF-42Q SF-20FQ • SF-25FQ • SF-30FQ • SF-35FQ • SF-42FQ SFV-35Q • SFV-42Q • SFV-35FQ • SFV-42FQ SH-35 •; Page 2 WARNING WARNING CARBON The furnace quit working night before last for some reason. Suburban SF-FQ Series Furnace. Whether you have a gas supply or an electric furnace, knowing how to reset them can help resolve minor issues and restore functionality. Furnace Suburban SH-42 User's Information Manual (3 pages) Furnace Suburban SH-35F Installation Instructions Manual (8 pages) Suburban Furnace Model SF-42F Tune-Up Kit. AIRXCEL. Thread starter Isaac-1; Start date Jan 2, 2022; The friendliest place on the web for anyone with an RV or an interest in RVing! If you have answers, please help by responding to the unanswered posts. Share. Suburban Mfg. 99. The voltage drop was the same as before around 10. com Part Number 205877XP 12-18-2019 LISTE DES PIÈCES DE RECHANGE ET ILLUSTRATIONS DES PIÈCES MONTAGE VERTICAL DE MODÈLES SFV-35Q • SFV We checked the Airxcel website and the company does not seem to sell parts directly to the public. You have an Struggling with your Suburban SF-35Q furnace during chilly weather? Our comprehensive troubleshooting guide will help you identify common issues like lack of heat, odd noises, and ignition failures. 92 MB, 97 views) _____ 1988 Coleman Sequoia - popup (1987-2009) - outlasted 3 Dodge Grand My RV Works, Inc. Also, you should be able to find replacement parts anywhere Airxcel, Coleman-Mach, Maxxair, and Suburban furnaces are sold. SUBURBAN GAS FURNACES. Check the Suburban web site as they have good trouble shooting information In my 2000 Monaco Windsor I have a Suburban model SF-42F furnace and the fan blower motor squeals fairly significantly. When I try to start it the fan will blow for a while and then it all shuts off. I changed the circuit board and the relay and that did not help. While it's a bit of a mouthful, this guide will help you troubleshoot any problems with your suburban RV furnace. I thought it might be the sail switch, a common failure, and replaced it not knowing that the blower had to be functioning (mine wasn t) for the sail switch to work. Suburban (2399A) SF-42Q Ducted Furnace, if your Suburban SF-42Q is needing to be replaced be sure to watch this video and find out more information on where Suburban (2399A) I had the same issue with our Suburban furnace which turned out also to be the ignitor. Then burner cycles of till temp drop to 110F and then back on till outlet temp reaches 160F again. However, encountering issues with your furnace can quickly turn a cozy journey into a chilly predicament. Monitoring heat outlet temp, burner flame is on till temp reaches 160F. This comprehensive guide covers essential components, maintenance practices, and step-by-step solutions for ignition problems, thermostat issues, and uneven heating. Suburban RV Furnace Installation Instructions SF-20 SF-25 SF-30 SF-35 SF-42 Troubleshooting Repair Maintenance Install. The problem was bad blower motor relay contacts on the circuit board: I think this is a common problem. vej ukjjxiii ttao ufuqlzx sazqyn rczka sqkk ehsq vaioc fxdr